All Categories

Get in touch

  • Feature
  • Parameter
  • get in touch
  • downloads

Application


 

Introducing our state-of-the-art UPS Tower, a sophisticated power solution tailored to meet the uninterrupted power supply needs of your critical equipment. This innovative UPS Tower stands out for its remarkable versatility and reliability, capable of handling a diverse range of input voltages with ease.

Designed with precision engineering and the latest technology, our UPS Tower guarantees unwavering power protection for your valuable systems and appliances. Whether you're operating in a 110V, 120V, or 127V environment, this UPS Tower offers seamless compatibility, ensuring your equipment receives the exact power it needs to function optimally.

The broad voltage compatibility of our UPS Tower makes it an ideal solution for various industries and applications, from data centers and server rooms to medical facilities and industrial operations. Its robust design and superior performance ensure that your critical equipment remains operational during power outages or voltage fluctuations, minimizing the risk of data loss or equipment damage.

 


Feature


  •  

 

Zero Transfer time:True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues.
DSP Digital Control Based:Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply
Three Level Inverter:Low harmony noise, high efficiency , well adapt to wide range of loading equipment, include high power laser printer, ultrasonic cleaner etc.
Ultra Wide Input Mains range:Strong compatible with ultra with electric environment, stay well with ultra wide range mains of  50V~145V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life
Best Loading Capability:Up to 0.9 Output Power Factor , 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application
Genset Compatible:Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.
High Input power factor:Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer
Reliable design:Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion.
Open to customization:Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system

 

  1.  


  2.  

FAQ


 

Do you have charging solution? 
A:Yes, BVT suitable for battery charging usage. In this application, our rectifier system is widely used for N+1 power supply and battery charging system management.

Does the product support the SNMP function?
A:Yes, 90% BVT product support SNMP. And all product built-in RS485 communication for standard. 

What is RS485?
A:RS485 is a communication interface, support real-time data communication function, and can use the monitoring software to monitor and control the working condition of the inverter power supply in a real-time manner. supply.(Optional)

Can the inverter adapt to high temperature and operate stably?
A:BVT supports a maximum temperature of -20℃~60℃, and the stable operation is unchanged. If you configure air conditioning cooling in a high temperature environment, the product life will be increased

Can the inverter power supply be used on the plane?
A:Currently not supported, because the height problem will affect the operation of the inverter and fail. Haibo ≥ 2000 meters, the inverter will fail and not work

How about the inverter load?
A:Super overload capacity, can withstand full load startup, with bypass switch, can switch to bypass power supply when overloaded

How about high frequency inverter power supply noise?
A:≤55dB

Can I choose the mains mode for my inverter power supply?
A:Yes, BVT inverter support AC main power supply and DC main power supply, 2 modes can be selected flexibly, and the mode can be changed through the LCD panel or the communication background software

What will causes Power failure and what can be done to resolve?
A: Check whether the positive and negative poles are reversed, and reconnect after confirming. If it cannot be turned on, please return the power supply back to BVT for inspection & repairing

What are the protection functions of the inverter power supply?
A:Input under-voltage protection, anti-DC input reverse connection, buffer protection, over-voltage protection, overload protection, short-circuit protection, over-temperature protection, temperature-controlled fan, etc.

 


Parameter table



Tower 1~3kVA LV Online UPS Datasheet(110V PF0.9 IEC62040)


Model 1K-LV 1KS-LV 2K-LV 2KS-LV 3K-LV 3KS-LV
Capacity VA/W 1kVA/900W 2kVA/1.8kW 3kVA/2.7kW
Topology Double Conversion Online UPS
Phase Single Phase Input Single Phase Output
AC
Mains Input
Wiring 1 phase 3wires ( L / N+PE)
Rated Voltage 110/115/120/127Vac
Voltage Range Line-Neutral: 55~145VAC
Frequency Range 40Hz~70Hz
Input Power Factor ≥0.99
AC Output Wiring 1 phase  L/N+PE
Output Voltage   110/115/120/127VAC
Voltage Regulation ±2%
Output Frequency 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
Waveform Pure Sine Wave
Distortion
(THDV%)
<2%(Linear Load)
<7%(None-Linear Load)
Over load capability 100%~105% continuous.
60Sec.@105%~130% Rated Load
10Sec.@130%~150% Rated Load
0.3Sec.@>150%Rated Load
Efficiency Line Mode 88% 89% 90%
Battery Mode 86% 87% 88%
Battery
&
Charger
Rated Battery Voltage ① 24VDC
Internal
36VDC
External
48VDC
Internal
72VDC
External
72VDC
Internal
72VDC
External
Battery Capacity 12V/7AH
x2pcs
External Battery Depends  12V/7AH
X4pcs
External Battery Depends  12V/7AH
X6pcs
External Battery Depends
Backup Time >6mins @ Half Load >6mins @ Half Load >6mins @ Half Load
Charging Current standard Model with Internal Battery:1A
Long Backup Time Model :4A
Optional Configuration to Order
  1. External Battery Module Connector for Standards Model
  2. Battery Capacity 7AH/9AH
  3. Battery Quantity(2/4/6pcs) or (3/6/6pcs)
Physical Chassis Style Tower
Tower Dimension
W x H x D (mm)
C1K, C1KS,:145*220*318mm/145*220*349mm
C2K, C2KS,C3K, C3KS:190 * 318*368mm
Weight (kg) 8.4 4.7 16.2 10.5 21.2 12
HMI LCD DISPLAY Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status
Standards
Communication Interface
1.RS232 PORT  2.EPO / ROO Port  3.Intelligent Slot  4.USB Card
Optional Extension Card
  1. NMC Card:  Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown
  2. CMC MODBUS Card,
  3. AS400 Relay Card
Operating Environment
Endurance
Temperature range -10~50oC
Relative Humidity 0-98%(Non-condensing)
Acoustics Noise <55dB @ 1 meters


 

Tower 6~10kVA LV Online UPS Datasheet(110V PF0.9 IEC62040)

 


Model 6K 6KS 10K 10KS
Capacity VA/W 6kVA/5.4kW 10kVA/9kW
Topology Double Conversion Online UPS
Phase Single Phase Input Single Phase Output
AC
Mains Input
Wiring 1 phase 3wires ( L / N+PE)
Rated Voltage 110/115/120/127Vac
Voltage Range Line-Neutral: 55~145VAC
Frequency Range 40Hz-70Hz
Input Power Factor ≥0.99
AC Output Wiring 1 phase  L/N+PE
Output Voltage   110/115/120/127VAC
Voltage Regulation ±2%
Output Frequency 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
Waveform Pure Sine Wave
Distortion
(THDV%)
<2%(Linear Load)
<8%(None-Linear Load)
Over load capability 10min@105%~125%
60s@125%~150%
0.5S@>150%
Efficiency Line Mode 91% 92%
Battery Mode 90% 92%
Battery
&
Charger
Rated Battery Voltage ① 192VDC
Internal
192VDC
External
192VDC
Internal
192VDC
External
Battery Capacity 12V/7AH
X16pcs
External Battery Depends  12V/7AH
X32pcs
External Battery Depends 
Backup Time >10mins @ Half Load >6mins @ Half Load
Charging Current standard Model with Internal Battery:1A
Long Backup Time Model :4A
Optional Configuration to Order
  1. External Battery Module Connector for Standards Model
  2. Battery Capacity 7AH/9AH
Physical Chassis Style Tower
Tower Dimension
W x H x D (mm)
6KS-LV:190 x 360x 5235
6K-LV: 190 x 456 x 535
10KS-LV: 238(W)X528(H)x540(D)mm
10K-LV : 300(W)X700(H)x700(D)mm
Weight (kg) 47 18 103 26.1
HMI LCD DISPLAY Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status
Standards
Communication Interface
1、RS232 PORT
Optional Extension Card   2、EPO / ROO Port  3、Intelligent Slot  4、USB Card (not HID)
  5、 NetWork Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown
  6、CMC MODBUS Card,   7、AS400 Relay Card
Operating Environment
Endurance
Temperature range -10~50oC
Relative Humidity 0-98%(Non-condensing)
Acoustics Noise <55dB @ 1 meters


GET IN TOUCH

Email Address *
Name
Phone Number
Company Name
Message *

Get a Free Quote

Our representative will contact you soon.
Name
0/100
Mobile
0/16
Email
0/100
Message
0/1000

Related Search

Wechat